Objectives Selector

Filters

Narrow your search for objectives by selecting from one or more of the categories below.

Contrast Techniques

Choose multiple


Objective Specifications

Choose one from each

Type
Magnification
Immersion

  • TypeAll
  • MagnificationAll
  • ImmersionAll

110 Objectives


  • CFI Plan Apo VC 60XWI

    Magnification: 60X
    N.A.: 1.2
    W.D.: 0.31–0.28mm

    • ideal for Brightfield
    • ideal for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, Multiphoton, Laser Trapping/Tweezers

  • CFI Plan Apo VC 20X

    Magnification: 20X
    N.A.: 0.75
    W.D.: 1mm

    • ideal for Brightfield
    • ideal for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI Plan Apo Lambda 40X

    Magnification: 40X
    N.A.: 0.95
    W.D.: 0.25–0.16mm

    • ideal for Brightfield
    • ideal for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI Plan Apo Lambda 10X

    Magnification: 10X
    N.A.: 0.45
    W.D.: 4mm

    • ideal for Brightfield
    • ideal for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI Plan Apo Lambda 20X

    Magnification: 20X
    N.A.: 0.75
    W.D.: 1mm

    • ideal for Brightfield
    • ideal for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI Plan Apo Lambda 60X

    Magnification: 60X
    N.A.: 0.95
    W.D.: 0.21–0.11mm

    • ideal for Brightfield
    • recommended for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI Plan Fluor 100XS Oil (with iris)

    Magnification: 100X
    N.A.: 0.5–1.3
    W.D.: 0.2mm

    • recommended for Brightfield
    • ideal for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research

  • CFI Plan Fluor 60XS Oil (with iris)

    Magnification: 60X
    N.A.: 0.5–1.25
    W.D.: 0.22mm

    • recommended for Brightfield
    • ideal for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research

  • CFI Apo 60XW NIR

    Magnification: 60X
    N.A.: 1
    W.D.: 2.8mm

    • ideal for Brightfield
    • suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, Multiphoton, Laser Trapping/Tweezers

  • CFI Apo 40XW NIR

    Magnification: 40X
    N.A.: 0.8
    W.D.: 3.5mm

    • ideal for Brightfield
    • suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, Multiphoton

  • CFI Plan Fluor 20XMI (multi-immersion)

    Magnification: 20X
    N.A.: 0.75
    W.D.: 0.35mm

    • recommended for Brightfield
    • recommended for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, Multiphoton

  • CFI Plan Fluor 40X

    Magnification: 40X
    N.A.: 0.75
    W.D.: 0.66mm

    • recommended for Brightfield
    • recommended for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Clinical/Laboratory, Research

  • CFI Plan Fluor 10X

    Magnification: 10X
    N.A.: 0.3
    W.D.: 16mm

    • recommended for Brightfield
    • recommended for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Clinical/Laboratory, Research

  • CFI S Plan Fluor ELWD 40X

    Magnification: 40X
    N.A.: 0.6
    W.D.: 3.6–2.8mm

    • recommended for Brightfield
    • recommended for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Tissue Culture, Research

  • CFI S Plan Fluor ELWD 20X

    Magnification: 20X
    N.A.: 0.45
    W.D.: 8.2–6.9mm

    • recommended for Brightfield
    • recommended for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Tissue Culture, Research

  • CFI S Plan Fluor ELWD 60X

    Magnification: 60X
    N.A.: 0.7
    W.D.: 2.62–1.8mm

    • recommended for Brightfield
    • recommended for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Tissue Culture, Research

  • CFI Plan Fluor 60X

    Magnification: 60X
    N.A.: 0.85
    W.D.: 0.4–0.31mm

    • recommended for Brightfield
    • recommended for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research

  • CFI Fluor 60XW

    Magnification: 60X
    N.A.: 1
    W.D.: 2mm

    • recommended for Brightfield
    • suitable for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, Multiphoton

  • CFI Fluor 40XW

    Magnification: 40X
    N.A.: 0.8
    W.D.: 2mm

    • recommended for Brightfield
    • suitable for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, Multiphoton

  • CFI Plan Fluor 20X

    Magnification: 20X
    N.A.: 0.5
    W.D.: 2.1mm

    • recommended for Brightfield
    • suitable for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Clinical/Laboratory, Research

  • CFI Fluor 20XW

    Magnification: 20X
    N.A.: 0.5
    W.D.: 2mm

    • recommended for Brightfield
    • suitable for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI S Fluor 20X

    Magnification: 20X
    N.A.: 0.75
    W.D.: 1mm

    • recommended for Brightfield
    • suitable for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research

  • CFI S Fluor 10X

    Magnification: 10X
    N.A.: 0.5
    W.D.: 1.2mm

    • recommended for Brightfield
    • suitable for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research

  • CFI S Fluor 40X

    Magnification: 40X
    N.A.: 0.9
    W.D.: 0.3mm

    • recommended for Brightfield
    • suitable for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research

  • CFI Apo TIRF 100X Oil

    Magnification: 100X
    N.A.: 1.49
    W.D.: 0.12mm

    • ideal for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, TIRF, N-SIM, N-STORM, Laser Trapping/Tweezers

  • CFI Plan 100XW

    Magnification: 100X
    N.A.: 1.1
    W.D.: 2.5mm

    • recommended for Brightfield
    • suitable for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, Multiphoton, Laser Trapping/Tweezers

  • CFI LWD 16XW

    Magnification: 16X
    N.A.: 0.8
    W.D.: 3mm

    • ideal for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, Multiphoton

  • CFI Plan Apo VC 60X Oil

    Magnification: 60X
    N.A.: 1.4
    W.D.: 0.13mm

    • ideal for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI Plan Apo VC 100X Oil

    Magnification: 100X
    N.A.: 1.4
    W.D.: 0.13mm

    • ideal for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI Apo TIRF 60X Oil

    Magnification: 60X
    N.A.: 1.49
    W.D.: 0.12mm

    • ideal for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, TIRF, Laser Trapping/Tweezers

  • CFI Plan Apo Lambda 100X Oil

    Magnification: 100X
    N.A.: 1.45
    W.D.: 0.13mm

    • ideal for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, TIRF, Laser Trapping/Tweezers

  • CFI Plan Fluor 10XW

    Magnification: 10X
    N.A.: 0.3
    W.D.: 3.5mm

    • recommended for Brightfield
    • suitable but not recommended for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research

  • CFI S Fluor 100X Oil (with iris)

    Magnification: 100X
    N.A.: 0.7–1.3
    W.D.: 0.2mm

    • recommended for Brightfield
    • ideal for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research

  • CFI Plan Apo NCG 100X Oil

    Magnification: 100X
    N.A.: 1.4
    W.D.: 0.17mm

    • ideal for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research

  • CFI Apo Lambda S 40XW

    Magnification: 40X
    N.A.: 1.25
    W.D.: 0.2–0.16mm

    • recommended for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, Multiphoton, Laser Trapping/Tweezers

  • CFI S Plan Fluor ELWD ADL 60X

    Magnification: 60X
    N.A.: 0.7
    W.D.: 2.62–1.8mm

    • recommended for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Tissue Culture, Research

  • CFI S Plan Fluor ELWD ADM 20X

    Magnification: 20X
    N.A.: 0.45
    W.D.: 8.2–6.9mm

    • recommended for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Tissue Culture, Research

  • CFI S Plan Fluor ELWD ADM 40X

    Magnification: 40X
    N.A.: 0.6
    W.D.: 3.6–2.8mm

    • recommended for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Tissue Culture, Research

  • CFI Apo Lambda S 60X Oil

    Magnification: 60X
    N.A.: 1.4
    W.D.: 0.14mm

    • recommended for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI Plan Fluor 40X Oil

    Magnification: 40X
    N.A.: 1.3
    W.D.: 0.2mm

    • recommended for Brightfield
    • not suitable for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI Plan Fluor 100X Oil

    Magnification: 100X
    N.A.: 1.3
    W.D.: 0.2mm

    • recommended for Brightfield
    • not suitable for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research, Laser Trapping/Tweezers

  • CFI LU Plan Fluor EPI P 50x

    Magnification: 50X
    N.A.: 0.8
    W.D.: 1mm

    • recommended for Brightfield
    • recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • ideal for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI S Fluor 40X Oil

    Magnification: 40X
    N.A.: 1.3
    W.D.: 0.22mm

    • recommended for Brightfield
    • not suitable for Darkfield
    • recommended for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research

  • CFI LU Plan Fluor EPI P 100x

    Magnification: 100X
    N.A.: 0.9
    W.D.: 1mm

    • recommended for Brightfield
    • recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • ideal for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI LU Plan Fluor EPI P 20x

    Magnification: 20X
    N.A.: 0.45
    W.D.: 4.5mm

    • recommended for Brightfield
    • recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • ideal for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI LU Plan Fluor EPI P 10x

    Magnification: 10X
    N.A.: 0.3
    W.D.: 17.3mm

    • recommended for Brightfield
    • recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • ideal for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI Plan Apo IR 60XW

    Magnification: 60X
    N.A.: 1.27
    W.D.: 0.17mm

    • suitable for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, N-SIM, Multiphoton, Laser Trapping/Tweezers

  • CFI Apo LWD 25XW

    Magnification: 25X
    N.A.: 1.1
    W.D.: 2mm

    • suitable for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal, Multiphoton

  • CFI Apo Lambda S LWD 40XW

    Magnification: 40X
    N.A.: 1.15
    W.D.: 0.61mm

    • suitable for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Research, Confocal, Multiphoton

  • CFI Plan Fluor 4X

    Magnification: 4X
    N.A.: 0.13
    W.D.: 17.2mm

    • recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Clinical/Laboratory, Research

  • CFI 100X Oil (with iris)

    Magnification: 100X
    N.A.: 0.5–1.25
    W.D.: 0.23mm

    • suitable for Brightfield
    • recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Clinical/Laboratory

  • CFI Plan Apo Lambda 4X

    Magnification: 4X
    N.A.: 0.2
    W.D.: 20mm

    • ideal for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI Plan Fluor DLL 20X

    Magnification: 20X
    N.A.: 0.5
    W.D.: 2.1mm

    • suitable but not recommended for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI Plan Fluor DLL 10X

    Magnification: 10X
    N.A.: 0.3
    W.D.: 16mm

    • suitable but not recommended for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI LU Plan Fluor EPI P 5x

    Magnification: 5X
    N.A.: 0.15
    W.D.: 23.5mm

    • recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • ideal for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI Plan Fluor DLL 40X

    Magnification: 40X
    N.A.: 0.75
    W.D.: 0.66mm

    • suitable but not recommended for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI S Fluor 4X

    Magnification: 4X
    N.A.: 0.2
    W.D.: 15.5mm

    • recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • ideal for Fluorescence

    Research

  • CFI Plan Apo Lambda DM 60X

    Magnification: 60X
    N.A.: 0.95
    W.D.: 0.21–0.11mm

    • suitable but not recommended for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • ideal for Phase Contrast
    • suitable but not recommended for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI Plan Apo Lambda DM 40X

    Magnification: 40X
    N.A.: 0.95
    W.D.: 0.25–0.16mm

    • suitable but not recommended for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • ideal for Phase Contrast
    • suitable but not recommended for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI Plan Apo Lambda DM 20X

    Magnification: 20X
    N.A.: 0.75
    W.D.: 1mm

    • suitable but not recommended for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • ideal for Phase Contrast
    • suitable but not recommended for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI LWD P 20X

    Magnification: 20X
    N.A.: 0.4
    W.D.: 3.9mm

    • suitable for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • ideal for Polarized Light
    • suitable for Fluorescence

    Education, Research

  • CFI P 10X

    Magnification: 10X
    N.A.: 0.25
    W.D.: 7mm

    • suitable for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • ideal for Polarized Light
    • suitable for Fluorescence

    Education, Research

  • CFI P 40X

    Magnification: 40X
    N.A.: 0.65
    W.D.: 0.65mm

    • suitable for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • ideal for Polarized Light
    • suitable for Fluorescence

    Education, Research

  • CFI Plan NCG 40X

    Magnification: 40X
    N.A.: 0.65
    W.D.: 0.48mm

    • suitable for Brightfield
    • suitable for Darkfield
    • suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Clinical/Laboratory

  • CFI Plan Apo Lambda 60X Oil

    Magnification: 60X
    N.A.: 1.4
    W.D.: 0.13mm

    • suitable for Brightfield
    • not suitable for Darkfield
    • ideal for DIC
    • not suitable for Phase Contrast
    • not suitable for Polarized Light
    • ideal for Fluorescence

    Research, Confocal

  • CFI Plan NCG 100X

    Magnification: 100X
    N.A.: 0.9
    W.D.: 1mm

    • suitable for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Clinical/Laboratory

  • CFI P 100X Oil

    Magnification: 100X
    N.A.: 1.25
    W.D.: 0.23mm

    • suitable for Brightfield
    • not suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • ideal for Polarized Light
    • recommended for Fluorescence

    Education, Research

  • CFI P 4X

    Magnification: 4X
    N.A.: 0.1
    W.D.: 30mm

    • suitable for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • ideal for Polarized Light
    • suitable for Fluorescence

    Education, Research

  • CFI Plan 50XH

    Magnification: 50X
    N.A.: 0.9
    W.D.: 0.35mm

    • suitable for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Clinical/Laboratory

  • CFI Plan Fluor DL 10X

    Magnification: 10X
    N.A.: 0.3
    W.D.: 15.2mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Tissue Culture, Research

  • CFI Plan Fluor DL 4X

    Magnification: 4X
    N.A.: 0.13
    W.D.: 16.5mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Tissue Culture, Research

  • CFI Plan Apo Lambda DM 100X Oil

    Magnification: 100X
    N.A.: 1.45
    W.D.: 0.13mm

    • suitable but not recommended for Brightfield
    • not suitable for Darkfield
    • not suitable for DIC
    • ideal for Phase Contrast
    • suitable but not recommended for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI Plan Fluor DLL 100X Oil

    Magnification: 100X
    N.A.: 1.3
    W.D.: 0.16mm

    • suitable but not recommended for Brightfield
    • not suitable for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI Plan Apo Lambda DM 60X Oil

    Magnification: 60X
    N.A.: 1.4
    W.D.: 0.13mm

    • suitable but not recommended for Brightfield
    • not suitable for Darkfield
    • not suitable for DIC
    • ideal for Phase Contrast
    • suitable but not recommended for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI Plan Fluor ADH 100X Oil

    Magnification: 100X
    N.A.: 1.3
    W.D.: 0.2mm

    • suitable but not recommended for Brightfield
    • not suitable for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Research

  • CFI S Fluor DL 20X

    Magnification: 20X
    N.A.: 0.75
    W.D.: 1mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Research

  • CFI 100X Oil

    Magnification: 100X
    N.A.: 1.25
    W.D.: 0.23mm

    • suitable for Brightfield
    • not suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • ideal for Fluorescence

    Education, Clinical/Laboratory, Laser Trapping/Tweezers

  • CFI 60X

    Magnification: 60X
    N.A.: 0.8
    W.D.: 0.25mm

    • suitable for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Education, Clinical/Laboratory

  • CFI Plan LWD IMSI 100X

    Magnification: 100X
    N.A.: 0.85
    W.D.: 0.95mm

    • suitable for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Clinical/Laboratory, Research

  • CFI Plan 20X

    Magnification: 20X
    N.A.: 0.4
    W.D.: 1.2mm

    • suitable for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Clinical/Laboratory

  • CFI Plan 40X

    Magnification: 40X
    N.A.: 0.65
    W.D.: 0.56mm

    • suitable for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Clinical/Laboratory

  • CFI Plan 10X

    Magnification: 10X
    N.A.: 0.25
    W.D.: 10.5mm

    • suitable for Brightfield
    • suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Clinical/Laboratory

  • CFI Plan Apo Lambda 2X

    Magnification: 2X
    N.A.: 0.1
    W.D.: 8.5mm

    • ideal for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • not suitable for Fluorescence

    Research

  • CFI S Fluor DLL 40X

    Magnification: 40X
    N.A.: 0.9
    W.D.: 0.3mm

    • suitable but not recommended for Brightfield
    • not suitable for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Research

  • CFI Plan Fluor DS 40X

    Magnification: 40X
    N.A.: 0.75
    W.D.: 0.72mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Clinical/Laboratory

  • CFI DS 10X

    Magnification: 10X
    N.A.: 0.25
    W.D.: 6.1mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • recommended for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Clinical/Laboratory

  • CFI 10X

    Magnification: 10X
    N.A.: 0.25
    W.D.: 7mm

    • suitable for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Education, Clinical/Laboratory

  • CFI 4X

    Magnification: 4X
    N.A.: 0.1
    W.D.: 30mm

    • suitable for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Education, Clinical/Laboratory

  • CFI 40X

    Magnification: 40X
    N.A.: 0.65
    W.D.: 0.65mm

    • suitable for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Education, Clinical/Laboratory

  • CFI Plan 100X Oil

    Magnification: 100X
    N.A.: 1.25
    W.D.: 0.2mm

    • suitable for Brightfield
    • not suitable for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • recommended for Fluorescence

    Clinical/Laboratory

  • CFI Plan 4X

    Magnification: 4X
    N.A.: 0.1
    W.D.: 30mm

    • suitable for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Clinical/Laboratory

  • CFI LWD 40XC

    Magnification: 40X
    N.A.: 0.55
    W.D.: 2.7–1.7mm

    • suitable for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable for Polarized Light
    • suitable for Fluorescence

    Tissue Culture

  • CFI Plan DL 10X

    Magnification: 10X
    N.A.: 0.25
    W.D.: 10.5mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Clinical/Laboratory, Tissue Culture

  • CFI DL 10X

    Magnification: 10X
    N.A.: 0.25
    W.D.: 7mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Education, Clinical/Laboratory

  • CFI DL 40X

    Magnification: 40X
    N.A.: 0.65
    W.D.: 0.65mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Education, Clinical/Laboratory

  • CFI LWD DL 20X

    Magnification: 20X
    N.A.: 0.4
    W.D.: 3.9mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Education, Tissue Culture

  • CFI LWD 20X

    Magnification: 20X
    N.A.: 0.4
    W.D.: 3.9mm

    • suitable for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable for Fluorescence

    Clinical/Laboratory, Tissue Culture

  • CFI Plan UW 2X

    Magnification: 2X
    N.A.: 0.06
    W.D.: 7.5mm

    • suitable for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • not suitable for Fluorescence

    Clinical/Laboratory

  • CFI Plan DL 20X

    Magnification: 20X
    N.A.: 0.4
    W.D.: 1.2mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Clinical/Laboratory

  • CFI Plan DL 40X

    Magnification: 40X
    N.A.: 0.65
    W.D.: 0.57mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Clinical/Laboratory

  • CFI Plan UW 1X

    Magnification: 1X
    N.A.: 0.04
    W.D.: 3.2mm

    • suitable for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • not suitable for Phase Contrast
    • recommended for Polarized Light
    • not suitable for Fluorescence

    Clinical/Laboratory

  • CFI BM 10XA

    Magnification: 10X
    N.A.: 0.25
    W.D.: 7mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Clinical/Laboratory

  • CFI LWD ADL 40XF

    Magnification: 40X
    N.A.: 0.55
    W.D.: 2.1mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Tissue Culture

  • CFI LWD ADL 40XC

    Magnification: 40X
    N.A.: 0.55
    W.D.: 2.7–1.7mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Tissue Culture

  • CFI LWD ADL 20XF

    Magnification: 20X
    N.A.: 0.4
    W.D.: 3.1mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Tissue Culture

  • CFI ADL 10X

    Magnification: 10X
    N.A.: 0.25
    W.D.: 6.2mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Tissue Culture

  • CFI LWD DL 20XF

    Magnification: 20X
    N.A.: 0.4
    W.D.: 3.1mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Tissue Culture

  • CFI LWD DL 40XC

    Magnification: 40X
    N.A.: 0.55
    W.D.: 2.7–1.7mm

    • suitable but not recommended for Brightfield
    • suitable but not recommended for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Tissue Culture

  • CFI DL 100X Oil

    Magnification: 100X
    N.A.: 1.25
    W.D.: 0.23mm

    • suitable but not recommended for Brightfield
    • not suitable for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Education, Clinical/Laboratory

  • CFI Plan DL 100X Oil

    Magnification: 100X
    N.A.: 1.25
    W.D.: 0.2mm

    • suitable but not recommended for Brightfield
    • not suitable for Darkfield
    • not suitable for DIC
    • suitable for Phase Contrast
    • suitable but not recommended for Polarized Light
    • suitable but not recommended for Fluorescence

    Clinical/Laboratory